302
>Hello World<Ctrl+Z>
OK
+CIPSEND: 2,11,11
AT+CIPSEND=2,
>Hello<ESC>
ERROR
AT+CIPSEND=?
+CIPSEND: (0-9), (1-1500)
OK
15.2.15 AT+CIPRXGET Get the network data manually
Description
This command is used to get the network data manually.
SIM PIN References
YES Vendor
Syntax
Test Command
Responses
AT+CIPRXGET=? +CIPRXGET: (0-4),(0-9),(1-1500)
OK
ERROR
Read Command Responses
AT+CIPRXGET? +CIPRXGET: <mode>
OK
ERROR
Execution Command Responses
(AT+CIPRXGET=1):
AT+CIPRXGET=<mode>,<
cid>[,<len>]
1. If <mode> = 0 or 1:
OK
2. If <mode> = 2 or 3:
+CIPRXGET: <mode>,<cid>,<read_len>,<rest_len>
<data>
OK
3. If<mode> = 4:
+CIPRXGET: 4,<cid>,<rest_len>
OK
SIMCOM CONFIDENTIAL FILE