EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
39
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
Examples
ATV1
OK
3.21 AT&F Set all current parameters to manufacturer defaults
Description
This command is used to set all current parameters to the manufacturer defined profile.
NOTE:List of parameters reset to manufacturer default can be found in defined values, factory
default settings restorable with AT&F[<value>].
Every ongoing or incoming call will be terminated.
SIM PIN References
NO V.250
Syntax
Execution Command Responses
AT&F[<value>] OK
Defined values
<value>
0 Set some temporary TA parameters to manufacturer defaults. The setting after power on or reset is
same as value 0.
default values
TA parameters VALUE
AT+ CAT R 0
AT+ CN MP 2
AT+CNAOP
7,9,4,2,5,3,11
AT+CTZU 0
AT+CVAUXV 2850
The default value of no CDMA/EVDO version is 7,9,5,3,11,2,4
Examples
AT&F