0 Don’t
report a list of current calls of ME automatically when the current call status
changes.
1 Report a list of current calls of ME automatically when the current call status changes.
<idX>
Integer type, call identification number, this number can be used in +CHLD command operations.
<dir>
0 mobile originated (MO) call
1 mobile terminated (MT) call
<stat>
State of the call:
0 active
1 held
2 dialing (MO call)
3 alerting (MO call)
4 incoming (MT call)
5 waiting (MT call)
6 disconnect
<mode>
bearer/teleservice:
0 voice
1 data
2 fax
9 unknown
<mpty>
0 call is not one of multiparty (conference) call parties
1 call is one of multiparty (conference) call parties
<number>
String type phone number in format specified by <type>.
<type>
Type of address octet in integer format;
128 Restricted number type includes unknown type and format
145 International number type
161 national number.The network support for this type is optional
177 network specific number,ISDN format
129 Otherwise
<alpha>
String type alphanumeric representation of <number> corresponding to the entry found in
phonebook; used character set should be the one selected with command Select TE Character Set
AT+CSCS.