EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
171
If text mode (AT+CMGF=1), command successful and SMS-
SUBMIT:
+CMGR:<stat>,<da>,[<alpha>][,<toda>,<fo>,<pid>,<dcs>,[<vp>],
<sca>, <tosca>,<length>]<CR><LF><data>
OK
If text mode (AT+CMGF=1), command successful and SMS-
STATUS-REPORT:
+CMGR: <stat>,<fo>,<mr>,[<ra>],[<tora>],<scts>,<dt>,<st>
OK
If text mode (AT+CMGF=1), command successful and SMS-
COMMAND:
+CMGR:<stat>,<fo>,<ct>[,<pid>,[<mn>],[<da>],[<toda>],<length
>]<CR><LF><data>
OK
If text mode (AT+CMGF=1), command successful and CBM
storage:
+CMGR:<stat>,<sn>,<mid>,<dcs>,<page>,<pages><CR><LF><d
ata>
OK
If PDU mode (AT+CMGF=0) and Command successful:
+CMGR:<stat>,[<alpha>],<length><CR><LF><pdu>
OK
+CMS ERROR: <err>
Defined values
<index>
Integer type; valu
e in the range of location numbers supported by the associated memory and start
with zero.
<stat>
1.Text Mode
"REC UNREAD" received unread message (i.e. new message)
"REC READ" received read message
"STO UNSENT" stored unsent message
"STO SENT" stored sent message
2. PDU Mode
0 received unread message (i.e. new message)
1 received read message.
2 stored unsent message.
3 stored sent message
<oa>
Originating-Address, Address-Value field in string format; BCD numbers (or GSM 7 bit default
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Related product manuals