EasyManuals Logo

SimCom SIM7500 Series User Manual

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
173
as two characters 2A (IRA 50 and 65)).
3 If <dcs> indicates that GSM 7 bit default alphabet is used:
a. If TE c
haracter set other than "HEX": ME/TA converts GSM alphabet into current
TE character set.
b. If TE character set is "HEX": ME/TA converts each 7-bit character of the GSM 7
bit default alphabet into two IRA character long hexadecimal numbers.
4 If <dcs> indicates that 8-
bit or UCS2 data coding scheme is used: ME/TA converts
each 8-bit octet into two IRA character long hexadecimal numbers.
<da>
Destination-Address, Address-
Value field in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
<vp>
Depending on SMS-SUBMIT <fo> setting: TP-Validity-Period either in integer format (default
167) or in time-string format (refer <dt>).
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<ra>
Recipient Address
GSM 03.40 TP-Recipient-Address Address-
Value field in string format;BCD numbers(or GSM
default alphabet characters) are converted to characters of the currently selected TE character
set(refer to command AT+ CSC S );type of address given by <tora>
<tora>
Type of Recipient Address
GSM 04.11 TP-Recipient-Address Type-of-Address octet in integer format (default refer <toda>)
<dt>
Discharge Time
GSM 03.40 TP-Discharge-Time in time-string format:yy/MM/dd,hh:mm:ss+zz,where characters
indicate year (two last digits),month,day,hour,minutes,seconds and time zone.
<st>
Status
GSM 03.40 TP-Status in integer format
0…255
<ct>
Command Type
GSM 03.40 TP-Command-Type in integer format
0…255
<mn>
Message Number
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals