Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
Syntax
Test Command Responses
AT+CPBR=?
+CPBR: (<minIndex>-<maxIndex>), [<nlength>], [<tlength>]
OK
+CME ERROR: <err>
Write Command Responses
AT+CPBR=
<index1>[,<index2>]
[+CPBR: <index1>,<number>,<type>,<text>[<CR><LF>
+CPBR: <index2>,<number>,<type>,<text>[…]]]
+CME ERROR: <err>
Defined values
<index1>
Integer type value in the range of location numbers of phonebook memory.
<index2>
Integer type value in the range of location numbers of phonebook memory.
Integer type.the current position number of the Phonebook index.
<minIndex>
Integer type the minimum <index> number.
<maxIndex>
Integer type the maximum <index> number
<number>
String type, phone number of format <type>, the maximum length is <nlength>.
<type>
Type of phone number octet in integer format, default 145 when dialing string includes international
access code character "+", otherwise 129.
<text>
String type field of maximum length <tlength>; often this value is set as name.
<nlength>
Integer type value indicating the maximum length of field <number>.
Integer type value indicating the maximum length of field <text>.
Examples
AT+CPBS?
OK