SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
207
by the context identification parameter <cid>
which is used when the MT sends an Activate PDP
Context Request message to the network.
A special form of the write command, AT+CGEQREQ=<cid> causes the req
uested profile for
context number <cid> to become undefined.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
AT+CGEQREQ=? +CGEQREQ: <PDP_type>,(list of supported <Traffic class>
s),(list
of supported <Maximum bitrate UL>s),(list of s
upported
<Maximum bitrate DL>s),(list of supported
<Guaranteed bitrate
UL>s,(list of supported <Guaranteed bitrate DL>
s),(list of
supported <Deliv ery order>s),(list of supported
<Maximum SDU
size>s),(list of supported <SDU error ratio>s),(list of supporte
d
<Residual bit error Ratio>s),(list of supported
<Delivery of
erroneous SDUs>s),(list of Supported <Transfer delay>
s),(list of
supported <Traffic handling priority>s),(list of supported <Source
statistics descriptor>s),(list of supported <Signaling indica
tion
flag>s)
OK
ERROR
Read Command Responses
AT+CGEQREQ? +CGEQREQ: [<cid>,<Traffic class>,<Maximum bitrate UL>,
<Maximum bitrate DL>,<Guaranteed bitrate UL>,<Guaranteed
bitrate DL>,<Delivery order>,<Maximum SDU size>,<SDU error
ratio>,<Residual bit error ratio>,<Delivery of erroneous SDUs>,
<Transfer Delay>,<Traffic handling priority>,<Source statistics
descriptor>,< Signaling indication flag>][<CR><LF>+CGEQREQ:
<cid>,<Traffic class>,<Maximum bitrate UL>,<Maximum bitrate
DL>,<Guaranteed bitrate UL>,<Guaranteed bitrate DL>,<Delivery
order>,<Maximum SDU size>,<SDU error ratio>,<Residual bit
error ratio>,<Delivery of erroneous SDUs>,<Transfer Delay>,
<Traffic handling priority>,<Source statistics descriptor>,
<Signaling indication flag> […]]
OK
ERROR
Write Command Responses
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals