Write Command
Responses
AT+CGQMIN=<cid>[,<prec
edence>[,<delay>[,<reliabilit
y>[,<peak> [,<mean>]]]]]
OK
ERROR
Execution Command Responses
AT+CGQMIN OK
ERROR
Defined values
<cid>
A numeric parameter which specifies a particular PDP context definition (see AT +CGDCONT
command). The range is from 1 to 24,100 to 179.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
<precedence>
A numeric parameter which specifies the precedence class:
0 network subscribed value
1 high priority
2 normal priority
3 low priority
<delay>
A numeric parameter which specifies the delay class:
0 network subscribed value
1 delay class 1
2 delay class 2
3 delay class 3
4 delay class 4
<reliability>
A numeric parameter which specifies the reliability class:
0 network subscribed value
1 Non real-time traffic,error-sensitive application that cannot cope with data loss
2 Non real-time traffic,error-sensitive application that can cope with infrequent data loss
3 Non real-time traffic,error-sensitive application that can cope with data loss, GMM/-
SM,and SMS
4 Real-time traffic,error-sensitive application that can cope with data loss
5 Real-time traffic error non-sensitive application that can cope with data loss
<peak>
SIMCOM CONFIDENTIAL FILE