217
AT+CGEQMIN=…,”5E3”,..).
0E0 subscribed value
5E2
“1E2”
“5E3”
“4E3”
“1E3”
“1E4”
“1E5”
“1E6”
“6E8”
<Delivery of erroneous SDUs>
This parameter indicates whether SDUs detected as erroneous shall be delivered or not.
0 no
1 yes
2 no detect
3 subscribed value
<Transfer delay>
This parameter indicates the targeted time between request to transfer an SDU at one SAP to its
delivery at the other SAP,in milliseconds.
The range is 0 and from 100 to 4000. The default value is 0. If the parameter is set to '0' the
subscribed value will be requested.
<Traffic handling priority>
This parameter specifies the relative importance for handling of all SDUs belonging to the UMTS
Bearer compared to the SDUs of the other bearers.
The range is from 0 to 3. The default value is 0.
If the parameter is set to '0' the subscribed value
will be requested.
<Source statistics descriptor>
This parameter indicates profile parameter that Source statistics descriptor for requested UMTS
QoS
The range is from 0 to 1. The
default value is 0. If the parameter is set to '0' the subscribed value
will be requested.
<Signaling indication flag>
This parameter indicates Signaling flag.
The range is from 0 to 1 The default value is 0. If the parameter is set to '0' the subscribed value will
be requested.
<PDP_type>
(Packet Data Protocol type) a string parameter which specifies the type of packet data protocol.
IP Internet Protocol
PPP Point to Point Protocol
IPV6 Internet Protocol Version 6
IPV4V6 Dual PDN Stack
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals