Syntax
Test Command Responses
AT+CLBSCFG=? +CLBSCFG: (0-1), (1-3),”Param Value
OK
Write Command Responses
AT+CLBSCFG=<operate>,<
para>[,<value>]
+CLBSCFG: 0,<para>,<value>
OK
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
Defined values
<operate>
A numeric parameter which specifies the operator.
0 read operator
1 write operator
<para>
A numeric parameter which specifies the operator parameter.
1 customer ID
2 Times have used positioning command
3 Servers address
lbs-simcom.com:3002
<value>
The value of parameter.
If <operate> is 1 and <para> is 1 or 3, <value> can be set.
Note:
1. When <operate> is 1 and <para> is 1, the length range of <value> is 1 to 20.
2. When <operate> is 1 and <para> is 3, the allowed <value> is "lbs-simcom.com:3002".
Server’s address of "lbs-simcom.com:3002" is free.
Examples
AT+CLBSCFG=?
+CLBSCFG: (0-1),(1-3),"Param Value"
OK
AT+CLBSCFG=0,1
SIMCOM CONFIDENTIAL FILE