80
Defined values
<mode>
0 automatic
1 manual
2 force deregister
3 set only <format>
4 manual/automatic
5
manual,but do not modify the network selection mode(e.g GSM,WCDMA) after
module resets.
NOTE: if <mode> is set to 1, 4, 5 in write command, the <oper> is needed.
<format>
0 long format alphanumeric <oper>
1 short format alphanumeric <oper>
2
numeric <oper>
<oper>
string type, <format> indicates if the format is alphanumeric or numeric.
<stat>
0
unknown
1 available
2 current
3 forbidden
<AcT>
Access technology selected
0 GSM
1 GSM Compact
2 UTRAN
7 EUTRAN
8 CDMA/HDR
NOTE: the value 8 do not follow the 3gpp spec, we add this value to distinguish cdma/hdr.
Examples
AT+COPS?
+COPS: 0,0,"China Mobile Com",0
OK
AT+COPS=?
+COPS: (2,"China Unicom","Unicom","46001",0),(3,"China Mobile Com","DGTMPT",
"46000",0),,(0,1,2,3,4,5),(0,1,2)
OK