Chapter 4
Troubleshooting
P/N 79000035_SM, Version 1.5 4 - 17 Focus 30/35 Service Manual
Tracker
Performance
Drives
Performance
Servo focus don’t
work.
Servo focus don’t move, a
high-pitched sound is
audible.
The spring is unhooked, replace it.
Replace servo focus hardware.
Item Fault / error message Description Solution / Notes
Subsystem error on
Control unit F2
Subsystem error: Tracker Check connectivity of Tracker camera
and transmitter.
Check firmware
Replace tracker hardware.
Item Fault / error message Description Solution / Notes
Subsystem error on
Control unit F2.
Subsystem error:Drive Check connectivity of motors and SCB
to MCB.
Check firmware
Replace hardware
Servo drive test V or
Hz shows
failed
The following messages could occure separately or in combination in
the
Program status/messageswindow:
A.
Vertical Coarse drive test failed. Some movements were
interrupted.Please check/adjust the Coarse drive.
B. For some movements the fine positioning did not succeed. Please
check at first the closing function of the clamp and further the Fine
drive.
C. Some movements did not start. Please check the correct function of
the clamp and further the Coarse drive.
Item Fault / error message Description Solution / Notes

Table of Contents

Other manuals for Spectra Precision Focus 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectra Precision Focus 30 and is the answer not in the manual?

Spectra Precision Focus 30 Specifications

General IconGeneral
BrandSpectra Precision
ModelFocus 30
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals