Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 18 P/N 79000035_SM, Version 1.5
Knobs
Performance
Distance meter - Dist V3
Performance
Message A occurs Repeat the Coarse drive adjustment,see
“Vertical Drive adjustment (for
adjustable drive only)” on page 6-118.
and see “Horizontal Drive adjustment
(for adjustable drive only)” on page 6-
126. Perform the test again. If the test
fails, then exchange the related Coarse
drive.
Message
A and B occurs Perform the Fine drive test. If it fails then
exchange the Fine drive otherwise the
Coarse drive.
Message
A and C occurs Repeat the Coarse drive adjustment,
otherwise exchange the Coarse drive.
Message
A,B and C occurs Repeat the Coarse drive adjustment and
perform Coarse and Fine drive test again.
If both fails again, exchange Coarse and
Fine drive.
The
Fine drive test V orHz interrupts without failure
message after a while.
The spindle of the Fine drive motor get
stuck in the tube or in the end stops.
Exchange Fine drives Hz or V.
The
Fine drive test V shows failed. Check if the red Blue tooth cable hinder
the Fine drive V, otherwise exchange the
Fine drive.
Item Fault / error message Description Solution / Notes
Item Fault / error message Description Solution / Notes
Subsystem error on
Control unit F2
Subsystem error:DistV3 Check connectivity of transmitter and
receiver board.
Check firmware
Replace hardware.