EasyManua.ls Logo

Spectra Precision Focus 30 - Radio short range test

Spectra Precision Focus 30
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6
Adjustment and Verification
P/N 79000035_SM, Version 1.5 6 - 113 Focus 30/35 Service Manual
Radio short range test
Performance
Item Performance Description Result Notes
1 Preparation Mount antenna on
instrument and external
device.
2 Start up a robotic radio
communication.
Set correct radio channel
and network on
instrument and external
device.
Connection
between
instrument and
controller.
3 Radio test at close
range.
A. Start up the
instrument in robotic
mode. Connect the
external controller
and call up the menu
Level Bubble....
B. Disconnect both
antennas from
instrument and
exteral controller.
C. Repeat the test
connecting the
antenna to the
instrument or the
external device.
The instrument
bubble should
be visible and
deliveres tilt
values.
Radio
communication
link should be
interrupted and
the tilt values
disappears.
Distance 0,2 - 4m
(0,6ft - 13ft)
Height difference
< 0,5m (1,6ft)
The instrument shows
the radio status
Connected.
The instrument shows
the radio status
Radio
link lost
.
Observe the
instrument status and
the bubble values.
4 Trouble shooting No radio or intermitting
connection.
1) Test the
instrument and
controller with
other known test
equipment.
2) Check
connection
cable and
antennas.
3) Replace the
radio modul on
outfigured
device.

Table of Contents

Other manuals for Spectra Precision Focus 30