Chapter 4
Troubleshooting
Focus 30/35 Service Manual 4 - 10 P/N 79000035_SM, Version 1.5
Error and eventlog viewer
Performance
4 Exit the program. Press the Close button to
exit the program.
Item Performance Action Result Notes
1 Start up instrument /
PASS.
See page 7-3 how to set-
up the instrument.
2 Start the error and
eventlog viewer
A. Select
Error and
eventlog viewer from
Instrument data in
Analyze and
pressOpen Report.
B. Open the report file
FocusInstruments_*.i
rep from your PC.
C. Check the single
sections for entries
and valid data.
The complete
instrument
report is shown.
The report file
consist of:
1) Headline
section with
instrument/
sensor serial
numbers and
instrument
corrections.
Sensor sections
with variables,
production data,
runtime data and
collector
messages.
The *.irep file
contains all
instrument data,
events and error
logs.The file name
contains the serial
number and current
date information.
Available sensors:
IM
TILT
ANGLE_HZ
ANGLE_VE
SERVOFOCUS
TRACKER
DRIVES
KNOBS
DISTV3
F2DISPLAY
Item Performance Action Result Notes

Table of Contents

Other manuals for Spectra Precision Focus 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectra Precision Focus 30 and is the answer not in the manual?

Spectra Precision Focus 30 Specifications

General IconGeneral
BrandSpectra Precision
ModelFocus 30
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals