Chapter 4
Troubleshooting
P/N 79000035_SM, Version 1.5 4 - 37 Focus 30/35 Service Manual
Unknown
Ok
Not communicating...
Not initialized...
Not active...
Timeout warning
Failed warning
Sensor specific messages Subsystem: FI_Darwin_Tracker
Performance
Sensor specific messages Subsystem: FI_Darwin_Servofocus
General status combined from communication status 1 - 6 and sensor specific messages A - D:
Unknown
Ok
Not communicating...
Not initialized...
Not active...
Timeout warning
Failed warning
Value Value description Status Ok Counter Error Counter
A
Target Ok 0 0- Ok status
1- Error message
Additional results
perfoming a
Diagnostics:
A1 Could NOT lock 1
times to prism.
Item System Monitor messages
and message codes stored in
*.fsmx file
Error Log stored in
*.irep file
Recommendation
24 Drive system "Target not
locked" C,C1
Tracker sensor"Target not
locked"A,A1
FI: 60 Code: 0x9c52
Message: Req xca got res 10
Check TSF-TLD cable
Check Tracker Camera/
Transmitter adjustment
Exchange Camera
Exchange Tracker transmitter

Table of Contents