Event Code Message Text and Description Details and Solution
4069
Configuring the drive default
map ID was not possible.
Ensure the drive is powered up, is
communicating with the library, and
has up to date firmware. If this error
persists, contact Spectra Logic
Technical Support. See Contacting
Spectra Logic on pageî ±11.
4071
Power supply fan failed. Verify the power supply fan is
spinning and ensure there are no
obstructions in the fan.
4072
No cleaning cartridge in
partition available for auto
cleaning.
Auto cleaning is enabled, but the
partition contains no labeled
cleaning cartridge. The library was
unable to perform the auto clean
function for one or more drives in
this partition. Install a valid and
labeled cleaning cartridge into the
partition and then perform a load
and unload on the drive that needs
to be cleaned to initiate the auto
cleaning.
4073
Medium source element
empty.
Check the source slot visually and
rescan inventory. Additionally check
for valid and readable barcode label.
4074
Medium source element
empty.
Check the source slot visually and
rescan inventory. Additionally check
for valid and readable barcode label.
4075
Cartridge lost while extracting
it from slot/drive.
Check the source element and ensure
that there are no obstructions in the
pathway of the robot.