POWER CONSUMPTION AND COOLING
REQUIREMENTS
The power and cooling requirements for the library depend on the number and type
of drives installed and number of library modules. The following table provides the
maximum power consumption and heat load for the base module fully loaded with
half-height and full-height drives and expansion modules fully loaded with half-
height and full-height drives. Use this information to calculate the total maximum
power consumption and heat load values, which can be used to build a power budget
for the library.
All values are measured at the AC input and include power supply efficiency. The
values are averages of observed hardware. In general, the lighter the load on the
power supplies, the less efficient they are. The power supply efficiency in turn affects
the power draw of all components.
Component
Power
Consumption
(watts)
Heat Load,
Continuous
(BTU/hour)
Spectra Stack with 3 Full-
Height Drives
151 515
Spectra Stack with 6 Half-
Height Drives
235 801
Spectra Stack and 6
Expansion Modules with
21 Full-Height Drives
883 3011
Spectra Stack and 6
Expansion Modules with
42 Half-Height Drives
1471 5016
LTO-9 Fibre Channel
Full-Height
• Read/write: 35 Read/write: 119
LTO-9 Fibre Channel or
SAS
Half-Height
• Read/write: 35 Read/write: 119
LTO-8 Fibre Channel
• Read/write: 40 Read/write: 136
JANUARY 2023 277
SPECTRA STACK LIBRARY
USER GUIDE
APPENDIX A - SPECIFICATIONS