The following settings are not saved in the backup configuration file:
The administrator password
Date and time
Library hostname
KMIP certificates
License keys
Library MAC address
Library, controller, and chassis serial numbers
Robot calibration data
Operator control panel calibration data
Library hardware configuration
Note: If you have previously saved a configuration backup file and want to use the file to
restore the library configuration, see Restoring the Library Configuration on the next
page.
Saving the Library Configuration
1. Login to the library as a user with administrator privileges.
2. Navigate to the Configuration > System > Save/Restore Configuration screen as
shown Figure14.
3. If necessary, click Save Configuration File to expand the section.
4. If you are using the OCP, insert a USB device into one of the USB ports on the
controller module.
5. Click Save.
Note: It takes approximately three minutes for the library to display Download and Cancel
buttons.
The destination location depends on how you are accessing the library:
RMI (RMI only) Downloads the configuration file through the browser to the
system running the RMI.
USB Device (OCP only) Downloads the configuration file to a USB device
inserted into the USB port on the front or the back of the library.
6. Click Download.
JANUARY 2023 62
SPECTRA STACK LIBRARY
USER GUIDE
CHAPTER 3 - CONFIGURING THE LIBRARY