ERROR EVENTS
Event Code Message Text and Description Details and Solution
2000
Failed to move cartridge. Verify the source and destination
elements and retry the move
operation.
2001
Failed to exchange the
cartridge.
2002
The initial module discovery
(detection of expansion
modules) failed.
Verify that all expansion modules are
powered on and that the expansion
interconnect cables are properly
installed.
2003
The library's temperature has
exceeded the critical limit.
1. Verify that the chassis fan in
each module is functioning
2. Verify that the drive cover
plates are installed in all open
drive bays.
3. Verify that all power supplies
are installed and working
properly.
4. Verify that the ambient room
temperature is within specified
limits.
2004
Library startup failed. 1. If the robotic assembly fails to
move through a certain area of
the library:
Look through the window in the
front panel and see if there are any
obstructions.
Verify that both magazines in that
module can be extended.
2. Verify that all modules have
power and that any expansion
modules are cabled correctly
with the expansion
interconnect cables.
JANUARY 2023 228