Event Code Message Text and Description Details and Solution
3. Verify that the top and bottom
cover plates are properly
installed on the library.
4. Verify that the module
alignment mechanisms at the
rear of the library are locked in
the proper positions.
5. Reboot the library.
6. If the robotic assembly moves
front to back, but not
vertically, the robot shipping
lock could be positioned
incorrectly and should be
moved to either the fully
locked or fully unlocked
position.
If the robotic assembly does not
unlock the shipping lock after reboot:
1. Move the robotic assembly to
the base from the Maintenance
> Move Robotic to Base
module screen. See Moving the
Robotic Assembly to the
Controller Module on
page206.
2. Power off the library.
3. Remove all cables from the
controller module and unlock
the alignment mechanism.
4. Extend the controller module
from the rack.
5. Reposition the lock.
Note: If the error persists, review library
events for additional information. See
Viewing Log Files on page195.