Event Code Message Text and Description Details and Solution
2005
Robotic spooling cable failure. Ensure that the spooling cable is
fully seated in the controller module
and correctly connected to the
robotic assembly.
2006
Cable to spooling mechanism
has failed.
2007
Move command failed due to
spooling mechanism failure.
2008
Exchange cartridge failed due
to spooling mechanism
failure.
2009
Library test failed due to
robotic assembly problem.
Review the test requirements and
retry the test. If the test continues to
fail, check for robotics obstructions
or other robotics problems.
2010
Library test failed due to
spooling mechanism defect.
Ensure that the spooling mechanism
is fully seated in the controller
module and installed correctly with
the robotic assembly.
2011
Drive power board has failed.
Some drives might be
powered off.
1. Ensure that the drive power
boards are fully seated in the
module. See Installing the New
Drive Power Board in Spectra
Stack DC-DC Converter
Replacement Instructions.
2. Power cycle the library.
2012
Multiple bottom covers
detected.
Remove all bottom covers except for
the bottom module in the library.
2013
Multiple top covers detected. Remove all top covers except for the
top module in the library.
2014
Bottom cover missing. If the controller module cannot
detect both a top and a bottom cover,
the robotic mechanism will not
move.
1. Install the bottom cover on the
bottom module in library.