Event Code Message Text and Description Details and Solution
4082
Magazine release motor
initialization failure.
Reboot the library and if the error
persists contact Spectra Logic
Technical Support. See Contacting
Spectra Logic on page11. If
magazines need to be removed to get
access to the tape cartridges, first
power down the library and then
release one by one magazine
manually. Only one magazine can be
open at a time.
4085
Too many retries of drive
command needed because of
UnitAttention or NotReady
condition.
Contact Spectra Logic Technical
Support. See Contacting Spectra
Logic on page11.
4086
Move operation failed due to
the inability accessing the
database.
Ensure the network the library is
connected to is operating normally
and ensure the library is running the
latest firmware. Library needs
reboot.
4088
Library not properly
calibrated. This may cause
media movement failures.
The library needs to be re-calibrated.
Reboot the library to initiate a re-
calibration of the system. Ensure the
library firmware is up to date. If this
event persists after a reboot of the
library, or if calibration does not
begin automatically upon restart,
login as the Service user and
manually initiate calibration via the
Maintenance > Auto Calibration RMI
menu.
4093
Could not obtain an IP address
from DHCP server.
Check the network configuration
settings and check if the DHCP
server is reachable. Use the network
configuration menu or unplug the
network cable and plug it in after a
few seconds to trigger an automatic
reconfiguration of the network
interface.
JANUARY 2023 248
SPECTRA STACK LIBRARY
USER GUIDE
CHAPTER 9 - EVENT CODES

Table of Contents

Related product manuals