Parameter Default Setting
Reset During
Reset
Default Settings
?
Library vendor ID - INQUIRY
vendor ID string (Std Inquiry
page)
Spectra
SCSI element addressing Starting element addresses
Values in decimal:
Slot: 1001
Picker: NA
Drives: 1
I/E slots: 101
Values in hexadecimal:
Slot: Ox3E9
Picker: NA
Drives: Ox1
I/E slots: Ox65
Yes
Miscellaneous Settings
Return drive serial numbers
to host
Enabled
Return barcodes to host (RES
SCSI data)
Enabled
Barcode format and length
returned to host
8 digits, left justified Yes
Language settings English Yes
Miscellaneous Settings Continued
Auto unload (library
controlled unload)
Enabled
Log tracing Continuous, all levels selected Yes
Ignore barcode media ID Disabled Yes