EasyManua.ls Logo

Svantek SVAN 948 - Page 26

Svantek SVAN 948
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SVAN 948 USER MANUAL
3 - 7
v DISPLAY (one of the main lists available after pressing the <MENU> push-button)
DISPLAY MODES (sub-list); it enables the user to activate ([
]) or switch off ([ ]) the available
modes of result’s presentation
§ SPECTRUM (position); available values: [
] or [ ]; this position is not active in the SLM or
VLM mode
§ 3 PROFILES (position); available values: [
] or [ ]
§ STATISTICS: (position); available values: [
] or [ ]
§ PLOT: (position); available values: [
] or [ ]
DISPLAY SETUP (sub-list)
§ CHANNEL x
DISPLAY SCALE: (sub-list)
o SCALE: (position); available values of the scale of graphical modes of the result’s
presentation:
LIN (linear), LOG (logarithmic) - in the case of vibration measurements and
LOG (logarithmic) - in the case of sound measurements
o DYNAMIC: (position); available values of the dynamics of graphical modes of the
result’s presentation: 80dB, 40dB, 20dB, 10dB
o X-ZOOM: (position); it informs the user about the multiplier for the horizontal axis
of the graphical modes of the result’s presentation): 1x
TOTAL VALUES
o TOTAL 1: (sub-list) enables to select the weighted filter to be used for the
calculation of the TOTAL value in the first profile
FILTER: (position); available values of the weighted filters:
in the case of sound measurements: A, SUSR1, SUSR2, SUSR3 or any
other sent to the unit by means of the interface
in the case of vibration measurements: HP, VUSR1, VUSR2, VUSR3 or
any other sent to the unit by means of the interface
TYPE: (position available only for vibration measurements); available values
if VUSR1, VUSR2 or VUSR3 was selected in the previous position: ACC,
VEL and DIL; if the HP filter was selected this position is not displayed
CAL. F.: (position available only for vibration measurements); accessible if
VUSR1, VUSR2 or VUSR3 was selected in the FILTER position; if the HP
filter was selected (the filter which was set in the 1
st
channel) this position is
not displayed; available values from -60.0dB to 60.0dB with 0.1dB or 1 dB
step
o TOTAL 2: (sub-list) enables one to select the weighted filter to be used for the
calculation of the TOTAL value in the second profile
FILTER: (position); available values of the weighted filters:
in the case of sound measurements: C, SUSR1, SUSR2, SUSR3 or any
other sent to the unit by means of the interface
in the case of vibration measurements: CH, VUSR1, VUSR2, VUSR3 or
any other sent to the unit by means of the interface
TYPE: (position available only for vibration measurements); available values
if VUSR1, VUSR2 or VUSR3 was selected in the previous position: ACC,
VEL and DIL; if the CH filter was selected (the filter which was set in the 2
nd
channel) this position is not displayed
CAL. F.: (position available only for vibration measurements); accessible if
VUSR1, VUSR2 or VUSR3 was selected in the FILTER position; if the CH
filter was selected (the filter which was set in the 2
nd
channel) this position is
not displayed; available values from -60.0dB to 60.0dB with 0.1dB or 1 dB
step

Table of Contents