128
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
ECONCRD (Output Connector Card Type)
This keyword sets the requirement for the output connector card type. If a card
type other than the type specified is detected, or this keyword’s value is set to
EMPTY and a card exists, an event (ECCRDMM) is generated stating an output
connector card mismatch. The keyword format is:
ECONCRD=<value>
Note:
Outputs are not disabled when the ECCRDMM event is generated.
Command Example:
RTRV-EQPT::OUTA-PG1:SC341:::PARAMETER=ECONCRD;
Response Example:
SYMMBITS 00-06-18 11:54:40
M SC341 COMPLD
"OUTA-PG1::ECONCRD = DONT-CARE"
;
Parameter Value Description
<value> DONT-CARE No card type requirement
CC CC card type
DS1 DS1 card type