140
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
IPEM2 (IP Address of Alternate Element Manager–Working
Memory)
This keyword sets the alternate element manager IP address in working memory.
The alternate element manager IP address is used for event reporting if
communication failure to the primary element manager occurs. Working memory
controls the actual operation of the network. The keyword format is:
IPEM2=<a.b.c.d>
Note:
Network parameters in working memory cannot be directly modified.
Command Example:
RTRV-EQPT::IMC:SC692:::PARAMETER=IPEM2;
Response Example:
SYMMBITS 00-06-18 11:46:43
M SC692 COMPLD
"IMC::IPEM2 = 0.0.0.0"
;
Parameter Value Description
a 0 to 255 Working memory alternate element manager IP
address
b0 to 255
c0 to 255
d0 to 255