TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
OQLEVEL (Output Quality Level)
This keyword specifies the SSM quality level for the specified output slot pair. This
SSM level is used when the Output Manual SSM function has been enabled
(OMANSSM=Y). The keyword format is:
OQLEVEL=<value>
Command Example:
RTRV-EQPT::OUTD:SC1010:::PARAMETER=OQLEVEL;
Response Example:
SYMMBITS 00-06-18 12:00:30
M SC1010 COMPLD
"OUTD::OQLEVEL = 4"
;
Parameter Value Description
<value> 1 Stratum 1 Traceable (PRS)
2 Synchronized – Traceability Unknown (STU)
3 Stratum 2 Traceable (ST2)
4 Transit Node Clock Traceable (TNC)
5 Stratum 3E Traceable (ST3E)
6 Stratum 3 Traceable (ST3)
7 SONET Minimum Clock (SMC)
8 Do not use for synchronization (DUS)