Page #150 background imageLoading...
Page #150 background image
150
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
IPSUBNET (Subnetwork Mask–Working Memory)
This keyword sets the subnetwork mask in working memory. The subnetwork
mask is used to extract the network identifier from the IP address. Working
memory controls the actual operation of the network. The keyword format is:
IPSUBNET=<a.b.c.d>
Note:
Network parameters in working memory cannot be directly modified.
Command Example:
RTRV-EQPT::IMC:SC782:::PARAMETER=IPSUBNET;
Response Example:
SYMMBITS 00-06-18 11:58:41
M SC782 COMPLD
"IMC::IPSUBNET = 255.255.248.0"
;
Parameter Value Description
a 0 to 255 Working memory subnetwork mask
b0 to 255
c0 to 255
d0 or 128

Table of Contents