Page #215 background imageLoading...
Page #215 background image
1
TimeHub 5500 TL1 Reference Manual
215
Performance Monitoring
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
44
Measurement Properties
Measurement property descriptions and factory settings are listed in Table K.
Table K. Measurement Properties
Measurement
Property Measurement Description
Factory
Setting
THR
Threshold value, in ns, for TDEV monitored type
0
Threshold value, in ns, for MRTIE monitored type
0
Threshold value, in ns, for LMRTIE monitored type
0
Threshold value, in ppm, for SPRD monitored type
0
Threshold value, in ppm, for FFOFF monitored type
0
CRI
Indicates whether an input port is qualified (Y) or
disqualified (N). Does not apply to SPRD or FFOFF
monitored types
N
RPT
Indicates whether an event is generated (Y) or not
generated (N) when a threshold is crossed
N
PM
Automatically displays (Y) or does not
automatically display (N) each new measurement
as it occurs
N
GOOD
Number of consecutive good measurements that
must occur following a bad measurement before an
input signal can be qualified and for the INMEAS
event to be cleared
1

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals