TimeHub 5500 TL1 Reference Manual
215
Performance Monitoring
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
44
Measurement Properties
Measurement property descriptions and factory settings are listed in Table K.
Table K. Measurement Properties
Measurement
Property Measurement Description
Factory
Setting
THR
Threshold value, in ns, for TDEV monitored type
0
Threshold value, in ns, for MRTIE monitored type
0
Threshold value, in ns, for LMRTIE monitored type
0
Threshold value, in ppm, for SPRD monitored type
0
Threshold value, in ppm, for FFOFF monitored type
0
CRI
Indicates whether an input port is qualified (Y) or
disqualified (N). Does not apply to SPRD or FFOFF
monitored types
N
RPT
Indicates whether an event is generated (Y) or not
generated (N) when a threshold is crossed
N
PM
Automatically displays (Y) or does not
automatically display (N) each new measurement
as it occurs
N
GOOD
Number of consecutive good measurements that
must occur following a bad measurement before an
input signal can be qualified and for the INMEAS
event to be cleared
1