3
TimeHub 5500 TL1 Reference Manual
185
Keywords
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
TCONST (Time Constant)
This keyword sets the loop tracking time constant for each input once the system
is fully warmed up. If a value other that those listed below is given, the nearest one
from the list below will be substituted. For example, if a value of 191 was assigned,
a value of 192 would be implemented. The keyword format is:
TCONST=<value>
Command Example:
RTRV-SYNC::CLK-4:SC1729:::PARAMETER=TCONST;
Response Example:
SYMMBITS 00-06-18 12:06:31
M SC1729 COMPLD
"CLK-4::TCONST = 49152"
;
Parameter Value Description
<value> 192 Time constant
768
3072
12288
49152