148
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
IPNE (IP Address of Network Element –Working Memory)
This keyword sets the network element (TimeHub 5500) IP address in working
memory. Working memory controls the actual operation of the network. The
keyword format is:
IPNE=<a.b.c.d>
Note:
Network parameters in working memory cannot be directly modified.
Command Example:
RTRV-EQPT::IMC:SC768:::PARAMETER=IPNE;
Response Example:
SYMMBITS 00-06-18 11:48:21
M SC768 COMPLD
"IMC::IPNE = 192.207.10.205"
;
Parameter Value Description
a 0 to 255 Working memory network element IP address
b0 to 255
c0 to 255
d0 to 255

Table of Contents