TRAFFIC (Traffic Data Pattern)
This keyword specifies a data pattern to be carried in the traffic time slots of the
output driver card.
Note:
255 (all ones) is the preferred value because this causes the greatest
number of clock pulses to occur.
The keyword format is:
TRAFFIC=<value>
Command Example:
RTRV-EQPT::OUTA:SC1769:::PARAMETER=TRAFFIC;
Response Example:
SYMMBITS 00-06-18 12:06:52
M SC1769 COMPLD
"OUTA::TRAFFIC = 255"
;
Parameter Value Description
<value> 127 Traffic pattern value that produces one
zero
191
223
239
247
251
253
254
255 Traffic pattern value that produces all ones