90
TimeHub 5500 TL1 Reference Manual
Commands
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
2
Retrieve Threshold Information
This command displays the threshold of a measurement for a particular input
channel. The command format is:
RTRV-TH[-TSG]::<aid>:<ctag>::<montype>;
Command Example:
RTRV-TH::CLK-2:SC1::LMRTIE-15M;
The command in this example displays the threshold value set for the
LMRTIE-15M measurement on input channel 2.
Parameter Value Variables Description
<aid> CLK — Use for SPRD measurements only
CLK-a a = 1 to 4 Input port number of clock card
<montype> FFOF-a a = 3S, 12S, 48S,
192S, 768S, 3072S
FFOF monitored type, where a is
the averaging time interval in
seconds
LMRTIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
LMRTIE monitored type, where a is
the observation time interval in
seconds (S), minutes (M), or hours
(H)
MRTIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
MRTIE monitored type, where a is
the observation time interval in
seconds (S), minutes (M), or hours
(H)
SPRD-a a = 3S, 12S, 48S,
192S, 768S, 3072S
SPRD monitored type, where a is
the averaging time interval in
seconds
TDEV-a a = 1S, 4S, 16S, 64S,
256S, 1024S
TDEV monitored type, where a is
the averaging time interval in
seconds
TIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
TIE monitored type, where a is the
observation time interval in
seconds (S), minutes (M), or hours
(H)