Page #130 background image
130
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
EPROT (Protection)
This keyword sets the requirement for output card protection. If the requirement is
not met, an event (EPROTMM) is generated stating an output protection mismatch,
but the outputs are enabled if possible. The keyword format is:
EPROT=<value>
Command Example:
RTRV-EQPT::OUTA:SC505:::PARAMETER=EPROT;
Response Example:
SYMMBITS 00-06-18 11:55:55
M SC505 COMPLD
"OUTA::EPROT = DONT-CARE"
;
Parameter Value Description
<value> DONT-CARE No requirement
REQUIRED Two output driver cards must be in the specified slot
pair