136
TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
INACTTIME (Inactivity Time-Out)
This keyword specifies the length of time a connection to the event reporting port
(PORTAO) will continue without the occurrence of an automatic output message.
The inactivity timer has a setting range of 0 to 10000, where each has a time value
of 0.1 seconds (100 ms). For example, a setting of 100 specifies that after
10 seconds without an automatic message, the connection to the TimeHub 5500
PORTAO will be closed. The connection will be re-established when another
automatic message occurs. The keyword format is:
INACTTIME=<value>
Command Example:
RTRV-EQPT::IMC:SC639:::PARAMETER=INACTTIME;
Response Example:
SYMMBITS 00-06-18 11:45:59
M SC639 COMPLD
"IMC::INACTTIME = 200"
;
Parameter Value Description
<value> 0 to
10000
Timeout in units of 100 ms