PIRANGESEC (Pull-In Range for Secondary Oscillator)
This keyword sets the pull-in range for the secondary oscillator; it applies only to
the clock card with the inferior oscillator when mixed clock oscillator types are
used in the TimeHub 5500 system.
This keyword can set how far off in fractional frequency the incoming signal can be
from the secondary oscillator and still have this clock card successfully track it.
The keyword format is:
PIRANGESEC=<value>
Command Example:
RTRV-EQPT::CLK:SC1071:::PARAMETER=PIRANGESEC;
Response Example:
SYMMBITS 00-06-18 12:01:04
M SC1071 COMPLD
"CLK::PIRANGESEC = 105"
;
Parameter Value Description
<value> 10 to 10000 Range in ppb (parts per billion = parts in 10
9
)