218
TimeHub 5500 TL1 Reference Manual
Performance Monitoring
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
4
Changing
Measurement properties can be specified for all input ports of a clock card or a
single input port of a clock card.
All Input Ports
To specify measurement properties for all input ports of a clock card, the command
format is:
ED-EQPT[-TSG]:[<tid>]:CLK0&&a:<ctag>:::
<montype>=THR-a&RPT-a&PM-a&GOOD-a;
a = 4 if clock card is 555xx-01 (5 input)
or
a = 8 if clock card is 555xx-02 (9 input)
Command Example:
ED-SYNC::CLK-0&&8:SC3:::TDEV-1s=THR-10;
Response Example:
SYMMBITS 01-06-01 10:25:04
M SC3 COMPLD
;