3
TimeHub 5500 TL1 Reference Manual
171
Keywords
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
QLEVEL (Quality Level)
This keyword specifies the assumed SSM quality level for the specified input
channel. This assumed SSM level is used when SSM has been disabled
(SSMENB=N). The assumed SSM level is always used for the PRC input. The
keyword format is:
QLEVEL=<value>
Command Example:
RTRV-SYNC::CLK-0:SC1293:::PARAMETER=QLEVEL;
Response Example:
SYMMBITS 00-06-18 12:02:38
M SC1293 COMPLD
"CLK-0::QLEVEL = 6"
;
Parameter Value Description
<value> 1 Stratum 1 Traceable (PRS)
2 Synchronized – Traceability Unknown (STU)
3 Stratum 2 Traceable (ST2)
4 Transit Node Clock Traceable (TNC)
5 Stratum 3E Traceable (ST3E)
6 Stratum 3 Traceable (ST3)
7 SONET Minimum Clock (SMC)
8 Stratum 4 Traceable (ST4)
9 Do not use for synchronization (DUS)