TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
WTRSS (Wait Time to Restore Synchronization Source)
This keyword sets the period of time (wait time) an input channel is provided to
re-establish all its operating parameters before it will be considered for use as a
synchronization source. The keyword format is:
WTRSS=<value>
Command Example:
RTRV-EQPT:::SC1801:::PARAMETER=WTRSS;
Response Example:
SYMMBITS 00-06-18 12:07:05
M SC1801 COMPLD
"CLK::WTRSS = 731"
;
Parameter Value Description
<value> 0 to 1000 Time in seconds