TimeHub 5500 TL1 Reference Manual
Keywords
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
3
QCUTOFF (Quality Cutoff)
This keyword specifies the minimum SSM quality level required for an input to be
used. SSM sync mode must be enabled (SYNCMDE=SSM) for this keyword to
operate. The input will be disqualified if the current SSM value exceeds QCUTOFF.
The keyword format is:
QCUTOFF=<value>
Command Example:
RTRV-SYNC::CLK-0:SC1206:::PARAMETER=QCUTOFF;
Response Example:
SYMMBITS 00-06-18 12:02:00
M SC1206 COMPLD
"CLK-0::QCUTOFF = 6"
;
Parameter Value Description
<value> 0 to 8 SSM quality level