80
TimeHub 5500 TL1 Reference Manual
Commands
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
2
Retrieve Performance Monitoring Information
This command displays the current set of performance monitoring data for one
input channel. The command format is:
RTRV-PM[-TSG]:[<tid>]:<aid>:<ctag>::<montype>;
Command Example:
RTRV-PM::CLK-4:SC1::MRTIE;
The command in this example displays MRTIE information about input channel 4.
Parameter Value Variables Description
<aid> CLK — Displays data for all input channels.
CLK-a a = 1 to 4 Displays data for input channel
specified.
<montype> FFOF-a a = 3S, 12S, 48S,
192S, 768S, 3072S
FFOF monitored type, where a is the
averaging time interval in seconds
LMRTIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
LMRTIE monitored type, where a is
the observation time interval in
seconds (S), minutes (M), or hours (H)
MRTIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
MRTIE monitored type, where a is the
observation time interval in seconds
(S), minutes (M), or hours (H)
SPRD-a a = 3S, 12S, 48S,
192S, 768S, 3072S
SPRD monitored type, where a is the
averaging time interval in seconds
TDEV-a a = 1S, 4S, 16S,
64S, 256S, 1024S
TDEV monitored type, where a is the
averaging time interval in seconds
TIE-a a = 1S, 1M, 15M,
30M, 1H, 2H, 8H,
24H
TIE monitored type, where a is the
observation time interval in seconds
(S), minutes (M), or hours (H)