TimeHub 5500 TL1 Reference Manual
81
Commands
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
Retrieve Performance Monitoring Information (cont’d)
Response Example:
SYMMBITS 98-09-05 12:07:38
M SC1 COMPLD
"CLK1-4:MRTIE-1S,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-1M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-15M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-30M,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-1H,2.000000,COMPL,,,75-MIN"
"CLK1-4:MRTIE-2H,NA,NA,,,75-MIN"
"CLK1-4:MRTIE-8H,NA,NA,,,75-MIN"
"CLK1-4:MRTIE-24H,NA,NA,,,75-MIN"
;
The response in this example indicates that MRTIE data has been collected over
the past 75 minutes (measurement time), and MRTIE values have been calculated
for observation times of 1 second, 1 minute, 15 minutes, 30 minutes, and 1 hour.
The values for observation times of 2 hours, 8 hours, and 24 hours are not yet
available because the system has not been running long enough to collect that
data. These values will become available as the unit continues to collect data. The
total measurement time is only indicated for MRTIE measurements and will
continue to increase in 15 minute increments for 24 hours. The <aid> field
indicates that this data was collected by clock card 1.
Once the measurement time reaches 24 hours, data prior to 24 hours will be lost
as new data is collected.
A specific measurement may be specified if only that one value is desired (for
example, RTRV-PM::CLK-4:SC1::MRTIE-1S;).