3
TimeHub 5500 TL1 Reference Manual
173
Keywords
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
RPTALL (Report All)
When this keyword is set to Y, events are not filtered based on whether a clock
card is active. The initial occurrence (setting) of the event condition, the clearing of
the event condition (for non-transient events), and the reporting of the event by
Retrieve Condition (RTRV-COND) or Retrieve Alarm Condition (RTRV-ALM) occur
regardless of whether the clock card is active. Examples:
The loss of an input signal is reported by both clock cards.
Both cards reports which input is being tracked.
When this keyword is set to N, redundant reports of input related events are
prevented. The keyword format is:
RPTALL=<value>
Note:
This keyword has no effect on the Event Log (each clock maintains its own
event log, and will log all of its events for which the LOG property is set to Y). The
Retrieve Log (RTRV-LOG) command may either specify which log is to be retrieved,
or, if it does not specify, the log from the “active” clock will be retrieved. By contrast,
however, the automatic output (AO) log only contains entries for those events that
were reported by automatic output messages.
Parameter Value Description
<value> Y Both clock cards report all active events
N Events are filtered from the inactive clock card

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals