3
TimeHub 5500 TL1 Reference Manual
141
Keywords
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
IPEM2X (IP Address of Alternate Element Manager–Auxiliary
Memory)
This keyword sets the alternate element manager IP address in auxiliary memory.
The alternate element manager IP address is used for event reporting if
communication failure to the primary element manager occurs. Auxiliary memory
contains a backup copy of network parameters in working memory (working
memory controls the actual operation of the network). The keyword format is:
IPEM2X=<a.b.c.d>
Command Example:
RTRV-EQPT::IMC:SC693:::PARAMETER=IPEM2X;
Response Example:
SYMMBITS 00-06-18 11:46:44
M SC693 COMPLD
"IMC::IPEM2X = 0.0.0.0"
;
Parameter Value Description
a 0 to 255 Auxiliary memory alternate element manager IP
address
b0 to 255
c0 to 255
d0 to 255