214
TimeHub 5500 TL1 Reference Manual
Performance Monitoring
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
4
Time Interval Error (cont’d)
Command Example:
RTRV-PM::CLK-4:SC1::TIE;
The response to the command in this example displays TIE information about
input port 4.
Response Example:
SYMMBITS 00-06-15 12:07:38
M SC1 COMPLD
"CLK1-4:TIE-1S,2.000000,COMPL"
"CLK1-4:TIE-1M,2.000000,COMPL"
"CLK1-4:TIE-15M,2.000000,COMPL"
"CLK1-4:TIE-30M,2.000000,COMPL"
"CLK1-4:TIE-1H,2.000000,COMPL"
"CLK1-4:TIE-2H,NA,NA"
"CLK1-4:TIE-8H,NA,NA"
"CLK1-4:TIE-24H,NA,NA"
;
The response in this example shows TIE values for observation time intervals of
1 second, 1 minute, 15 minutes, 30 minutes, and 1 hour for input port 4 of clock
card 1. The values for time intervals of 2 hours, 8 hours, and 24 hours are not yet
available, but will become available as the system collects data.