1
TimeHub 5500 TL1 Reference Manual
201
Performance Monitoring
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
44
Frequency Spread (cont’d)
Response Example:
SYMMBITS 01-05-31 10:46:29
M SC1 COMPLD
"CLK-1:SPRD-3S,2.000000,COMPL"
"CLK-1:SPRD-12S,2.000000,COMPL"
"CLK-1:SPRD-48S,2.000000,COMPL"
"CLK-1:SPRD-192S,2.000000,COMPL"
"CLK-1:SPRD-768S,NA,NA"
"CLK-1:SPRD-3072S,NA,NA"
;
The response in this example shows SPRD values calculated for averaging times of
3 seconds, 12 seconds, 48 seconds, and 192 seconds. The values for averaging
times of 768 seconds and 3072 seconds are not yet available, but will become
available as the system collects data.