2
TimeHub 5500 TL1 Reference Manual
43
Commands
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
Edit Equipment (cont’d)
Note:
For detailed descriptions of keywords, see the Keywords chapter.
ED-EQPT[-TSG]:[<tid>]:<aid>:<ctag>:::<event>=<value>;
Parameter Value Variables Description
<keyword> RPTALL Report All
SCRAMBLE Scramble Communication
SNGCLK Single Clock Operation
SPRDCHN Spread Channels
SYNCMDE Sync Mode
TIDQUIET TID Quiet
TRAFFIC Traffic Data Pattern
WTRSS Wait Time to Restore Synchronization
Source
<value> See the Keywords chapter
Parameter Value Variables Description
<aid> CLK Clock card
IMC Management card
Sa-OUTb a = 1 Shelf number
b = A, B, C, or D Output driver card letter
<event> CLKGONE Fail alarm
CLKFAIL
CLKWARM
EXCD24HR
ECCRDMM
EPROTMM
NVERROR
OPCDFL
OPCDNA
OPCDNP
SNFAIL