2
TimeHub 5500 TL1 Reference Manual
45
Commands
097-55501-02 Issue 5: June 2003
2
5
3
SSSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS
Edit Equipment (cont’d)
Note:
For detailed descriptions of keywords, see the Keywords chapter.
ED-EQPT[-TSG]:[<tid>]:<aid>:<ctag>:::<measurement>=<value>;
Note:
For detailed descriptions of keywords, see the Keywords chapter.
Parameter Value Variables Description
<event> NETCLOS — Event
CLKCDIN
OPCDIN
SNSAVL
SNSSM
SNOPER
SNTRCK
TRAOOR
<value> See the Keywords chapter
Parameter Value Variables Description
<aid> CLK — Clock card
IMC Management card
Sa-OUTb a = 1 Shelf number
b = A, B, C, or D Output driver card letter
<measurement> FFOF — Fractional Frequency Offset
LMRTIE Latest Maximum Relative Time Interval
Error
MRTIE Maximum Relative Time Interval Error
SPRD Frequency Spread
TDEV Time Deviation
TIE Time Interval Error
<value> See the Keywords chapter