88
TimeHub 5500 TL1 Reference Manual
Commands
097-55501-02 Issue 5: June 2003
SSSSSSSSSSS SSSS S SSSSS SSSSSSS S SSS S SSSSS S
2
Retrieve Sync (cont’d)
RTRV-SYNC[-TSG]:[<tid>]:<aid>:<ctag>:::
PARAMETER=<measurement>;
Command Examples:
RTRV-SYNC::S2-OUTA-3:SC1:::PARAMETER=SQUELCH;
The command in this example displays squelch information about Output Channel
3 on Output Card A in shelf 2.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY;
The command in this example displays the priority of input channel 3.
RTRV-SYNC::CLK-3:SC1:::PARAMETER=PRIORITY&ENABLE;
The command in this example displays the priority of input channel 3 and whether
it is enabled.
Parameter Value Variables Description
<aid> CLK-a
a = 1 to 4
Input channel number of clock card
Sa-OUTb-c
a = 1
Shelf number
b = A, B, C, or D
Output driver card letter
c = 1 to 40
Output port number
<measurement> FFOF — Fractional Frequency Offset
LMRTIE Latest Maximum Relative Time
Interval Error
MRTIE Maximum Relative Time Interval
Error
SPRD Frequency Spread
TDEV Time Deviation
TIE Time Interval Error